Anchor and rock bolt pull-out testing — what it measures, who asks for it, how it is done

Drill diameter, grout, bond between bar and ground — all of these are assumptions in the anchor design. The pull-out test turns the assumption into a measurement, one anchor at a time.

Updated: 13 September 2026 · Artusa Oman engineering team · 2 min read

What it measures

A single-direction tensile load is applied to an installed anchor or rock bolt and the load–displacement behaviour is recorded. It answers one question: does this anchor, in this ground, carry the force the calculation has assigned to it? The bond between grout and ground, the drill diameter and the placement of the bar are assumed in the design; the test measures the result.

Why it is done

ReasonWhat is learned
WorkmanshipThat drilling, grouting and bar placement were carried out as specified
CapacityThat the anchor carries the required load for its design failure mode — pull-out, cone failure in rock or concrete, steel failure
Design verificationWhether the ground–grout bond matches the value used in the calculation; anchor length corrected if not

The test alone is not enough: the anchor bar's certificates (European Technical Assessment where applicable, material certificates, corrosion protection) go into the file together with the test records.

Who asks for it

How it is done

A hydraulic jack and a load cell are seated on the anchor head; displacement is read with a dial gauge or transducer. The load is applied in the stages given in the specification, held for the stated time at each stage, and permanent and elastic displacement are separated. The result is delivered as a load–displacement graph and a signed record. The acceptance criterion — test load and admissible displacement — comes from the specification; it is not improvised on site.

The record becomes part of the line's acceptance file; later inspections compare the anchor head with it. The service is independent of the system: we test anchors and bolts of any manufacturer, on our own lines and on others'.

An anchor that has never been tested is a number in a calculation. A tested anchor is a measured fact in the file.

Questions on this topic

How many anchors are tested?

The number and the test load come from the specification — typically one test per stated number of anchors under EN 1537 or EN 14490. Where the specification is silent we propose a sampling programme.

Does the test damage the anchor?

No. The test load and the displacement limit are chosen so that a sound anchor stays within its elastic range; only an anchor that fails the criterion is rejected and replaced.

Sources

  • EN 1537, Execution of special geotechnical work — Ground anchors.
  • EN 14490, Execution of special geotechnical work — Soil nailing.